Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Braz. dent. j ; 28(1): 30-34, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839118

ABSTRACT

Abstract Sonic vibrations may improve the bond strength and durability of fiberglass posts by improving adhesive penetration into dentin as well as the cement flow. The objective of this study was to evaluate the effect of sonic vibrations on the bond strength between fiberglass posts and root dentin using the pull-out test. Bovine roots were endodontically treated and divided randomly into four groups (n=12): Group C - conventional cementation (control); Group SA - sonic vibration (Smart Sonic Device, FGM) of the adhesive system and conventional post accommodation; SP group - conventional adhesive application and sonic vibration of the post during accommodation; and SASP - sonic vibration of the system adhesive and the post during accommodation. The posts were cleaned, treated with a silane and adhesive system (Ambar, FGM), and cemented with a dual-cured resin cement (Allcem Core, FGM). After 24 h, the specimens were subjected to mechanical tests and failure analyses. Representative specimens were analyzed by a scanning electron microscope to observe the cementation line. The results were analyzed using ANOVA and Tukey's test (a=5%). The bond strengths were as follows: SASP (90.9±27.1 N), C (121.4±60.6 N), SA (127.6±31.8 N) and SP (156.4±41.3 N). The use of sonic vibrations during the application of adhesive or post cementation separately did not affect the bond strength but had a negative effect when used for both procedures.


Resumo Vibrações sônicas podem melhorar a resistência e a durabilidade da união de pinos de fibra de vidro, melhorando a penetração do sistema adesivo à dentina, bem como o escoamento do cimento. O objetivo deste estudo foi avaliar o efeito da vibração sônica na resistência de união de pinos de fibra de vidro à dentina radicular, através de ensaio pull out. Raízes bovinas tratadas endodonticamente foram preparadas e divididas aleatoriamente em quatro grupos (n=12): Grupo C - cimentação convencional, (controle); Group SA - vibração sônica (Smart Sonic Device(r), FGM) do sistema adesivo e assentamento convencional do pino; grupo SP - aplicação convencional do sistema adesivo e vibração sônica no assentamento do pino; e SASP - vibração sônica do sistema adesivo e no assentamento do pino. Os retentores foram limpos, tratados com silano e sistema adesivo (Ambar, FGM) e cimentados com cimento resinoso dual (Allcem Core, FGM). Após 24 h as amostras foram submetidas ao teste mecânico e análise de falha. Amostras representativas foram avaliadas sob microscópio eletrônico de varredura, para avaliação da linha de cimentação. Os resultados foram analisados por meio de análise de variância e teste de Tukey (a=5%). Os resultados obtidos foram: SASP (90,9±27,1 N, C (121,4±60,6 N), SA (127,6±31,8 N) e SP (156,4±41,3 N). A vibração sônica para aplicação apenas do sistema adesivo ou pino não afetou a resistência de união, entretanto interferiu negativamente quando utilizada para ambos procedimentos.


Subject(s)
Animals , Cattle , Dentin/chemistry , Glass , Post and Core Technique , Tooth Root/chemistry , Vibration , Dentin-Bonding Agents/chemistry , In Vitro Techniques , Microscopy, Electron, Scanning
2.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-794217

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Humans , Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
3.
Bauru; s.n; 2015. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867423

ABSTRACT

A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação...


The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment...


Subject(s)
Computer-Aided Design , Crowns , Ceramics/chemistry , Dental Prosthesis Design/methods , Zirconium/chemistry , Analysis of Variance , Dental Marginal Adaptation , Hot Temperature , Materials Testing , Reference Values , Tensile Strength , Tomography, X-Ray Computed
4.
J. appl. oral sci ; 22(3): 209-217, May-Jun/2014. tab, graf
Article in English | LILACS, BBO | ID: lil-711709

ABSTRACT

Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. Objectives: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant. .


Subject(s)
Acrylic Resins/chemistry , Dental Alloys/chemistry , Dental Porcelain/chemistry , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Dental Veneers , Analysis of Variance , Compressive Strength , Dental Casting Technique , Dental Stress Analysis , Materials Testing , Palladium/chemistry , Reference Values , Reproducibility of Results , Silver/chemistry , Surface Properties , Tensile Strength , Time Factors
5.
Rev. odontol. UNESP (Online) ; 42(3): 196-203, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-678423

ABSTRACT

Introdução: A estabilidade dimensional das resinas acrílicas influencia na adaptação das coroas provisórias e, consequentemente, no resultado do tratamento reabilitador. Objetivo: Avaliar a estabilidade dimensional, ao longo do tempo, de uma resina acrílica processada de diferentes maneiras. Material e Método: Cinco técnicas de polimerização da resina acrílica foram testadas: I - polimerização térmica utilizando líquido de polimerização rápida em mufla; II - autopolimerização sob pressão; III - autopolimerização utilizando pincel; IV - autopolimerização após mistura (pó + líquido) em pote Dappen e inserção em matriz de aço na fase arenosa; V - autopolimerização após mistura em pote Dappen com inserção na matriz metálica na fase plástica. Foram confeccionados dez corpos de prova para cada tipo de processamento. Avaliou-se a estabilidade dimensional por meio de matriz de aço inox confeccionada segundo a especificação nº19 da ADA. Os corpos de prova foram armazenados em água destilada a 37ºC e examinados nos períodos de 1 hora, 1, 7, 15, 10, 90 e 180 dias após a polimerização, com o auxílio de um microscópio óptico com aumento de 20×. Os resultados foram submetidos à análise de dupla variância (Teste de Tukey para Tempo e Técnica de processamento) em nível de 5% de significância. Resultado: Todos os grupos experimentais apresentaram alterações dimensionais entre o sétimo e o 15º dia; após esse período de tempo, houve alterações dimensionais estatisticamente significantes, para as diferentes técnicas estudadas. Conclusão: A estabilidade dimensional da resina acrílica não sofreu influência das diferentes técnicas de processamento avaliadas; entretanto, foi influenciada pelo tempo de armazenamento.


Introduction: The dimensional stability of acrylic resins influences the temporary crowns fitting and can affect the final restoration results. Objective: To evaluate the long-term dimensional stability of an acrylic resin used for fabrication of provisional crowns. Material and Method: Five types of processing techniques were evaluated: I - thermal polymerization using fast polymerization liquid and flask; II - auto-polimerization under pressure in a stainless steel matrix; III - auto-polimerization using the bead brush technique to build the sample; IV - auto-polimerization after mixture (powder + liquid) in a dappen dish and insertion in a stainless steel matrix at the sand stage; V - auto-polimerization after mixture in a dappen dish with insertion in a stainless steel matrix at the plastic stage. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of a steel matrix made following the ADA specification nº19. The samples were stored in distilled water at 37 ºC and examined at the periods of 1 hour, 1, 7, 15, 30, 90 and 180 days, with an optic microscope with 20× magnification. The results were subjected to the 2-way analysis of variance (Tukey Test) at the significance level of 5% for the variables Time and Processing Technique. Result: All samples had dimensional alterations from day 7 to the day 15, regardless of the technique used. From day 15 to 180, there were no statistically significant dimensional alterations. Conclusion: The dimensional stability of the acrylic resin was not influenced by the different processing techniques tested, however, it was influenced by the storage time.


Subject(s)
Acrylic Resins , Dental Marginal Adaptation , Polymethyl Methacrylate , Crowns , Dental Restoration, Temporary , Denture, Partial, Fixed , Analysis of Variance , Data Interpretation, Statistical , Microscopy
6.
Braz. dent. sci ; 16(2): 44-50, 2013. ilus, tab
Article in English | LILACS, BBO | ID: lil-698289

ABSTRACT

Objective: This study aimed at evaluating the micro-hardness of an acrylic resin used for provisional crowns. Materials and methods: Five different processing techniques (direct and indirect) were assessed: (I) auto polymerizing resin in sandy stage; (II) auto polymerizing resin in plastic stage; (III) bead-brush technique; (IV) auto polymerizing resin under pressure; (V) heatcured acrylic resin under pressure. Five specimens were made for each test group. For the initial micro-hardness test, the specimens were immersed in deionized water for 48 hours. For the analysis of the final micro-hardness, the specimens were subjected to pH-cycling to simulate the changes in the pH level which occur in the oral cavity. Results: Tests revealed that the micro-hardness was decreased after the pH-cycling. However, no statistical difference was found among the different types of acrylic resin polymerization techniques. Conclusion: It was concluded that the micro-hardness is not directly related to the polymerization technique for making provisional


Objetivo: Avaliou-se a dureza superficial de uma resina acrílica (PMMA) utilizada para a confecção de coroas provisórias. Material e Métodos: Cinco diferentes técnicas de processamento (Direta e Indireta) para polimerização da resina foram testadas: I - autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de silicona na fase arenosa; II - autopolimerização após mistura em pote dappen com inserção em matriz de silicona na fase plástica; III - autopolimerização utilizando a técnica do pincel; IV - autopolimerização sob pressão em matriz de silicona; V - polimerização térmica utilizando líquido de polimerização rápida em mufla. Foram confeccionados cinco corpos-de-prova para cada grupo. Para o teste de microdureza inicial os espécimes foram imersos em água deionizada por 48 horas. Para a análise da dureza final, os espécimes foram submetidos a ciclos dinâmicos de pH, para simular a variação de pH ocorrida na cavidade oral. Resultados: Os testes revelaram que houve diminuição da dureza do material após a ciclagem ácida, porém não foi verificada diferença estatística entre os diferentes tipos de processamento da resina acrílica. Conclusão: Concluiu-se que a microdureza não está relacionada diretamente com a técnica de confecção dos provisórios.


Subject(s)
Acrylic Resins , Crowns , Dental Prosthesis , Denture, Partial, Temporary
7.
RGO (Porto Alegre) ; 58(2): 239-242, abr.-jun. 2010.
Article in Portuguese | LILACS, BBO | ID: biblio-874111

ABSTRACT

Diversos estudos têm mostrado altas frequências de sucesso na reabilitação oral por meio de implantes dentários. Entretanto, podem ocorrer fracassos por complicações logo após a sua instalação ou, posteriormente, quando a prótese sobre o implante já está em função há algum tempo. As falhas tardias podem ocorrer em situações nas quais a osseointegração de um implante previamente estável e em função é perdida por sobrecarga e/ou infecção, sendo que, um dos fatores de infecção é a infiltração de bactérias através de falhas existentes na conexão implante/pilar. Com essas considerações, o objetivo deste trabalho foi, de por meio de uma revisão de literatura discorrer sobre a infiltração de fluídos e bactérias no interior dos implantes, que ocorre devido à falha na conexão implante/pilar protético. Concluiu-se que mesmo com o desenvolvimento de novos implantes e pilares e a tentativa de alguns autores de buscarem o vedamento dessa microfissura a infiltração bacteriana entre implante/pilar não foi evitada.


Many studies have shown high rates of successful oral rehabilitation with implants. However, complications may occur immediately after the implant is placed or some time later, when the prosthesis has already been used for some time. These complications may lead to implant failure. Late failures can happen in situations where the osseointegration of a previously stable and functional implant is lost because of an overload and/or an infection. One of the causes of infection is the infiltration of bacteria in failures present in the implant-abutment interface. With this in mind, the purpose of this study was to address the infiltration of liquids and bacteria inside the implant due to failures in the implant-abutment interface based on a literature review. In conclusion, despite the development of new implants and abutments and the attempts of some authors to seal microfissures, bacterial infiltration in the implant-abutment interface still occurred.


Subject(s)
Periodontal Diseases , Dental Implants , Bacterial Infections , Dental Leakage/complications
SELECTION OF CITATIONS
SEARCH DETAIL